COMPARISON OF RESIDENTIAL BUILDING
WITHOUT RUBBER-STEEL BEARINGS
AND WITH RUBBER-STEEL BEARINGS
More details
Hide details
1 |
National University of Architecture and Construction of Armenia |
Publication date: 2018-02-21
BoZPE 2014;(2):125–132
KEYWORDS
TOPICS
ABSTRACT
In the article there are presented calculations of 17 stories cast in situ reinforce
concrete frame-wall residential building without rubber-steel (further r/s) bearings
and with r/s bearings, under influence of seismic forces and torsion moments.
The building has three spans in one direction and four in the other. Horizontal
seismic load Q and torsion moment Mkкр are identified, which have influence on the
building, the results are inserted into the program packet “LIRA 9.6 R9”. As it was
mentioned above, appropriate calculations were made without r/s isolators and with
r/s isolators and were reinforced via “LIR-ARM”. Then, the following characteristics
were compared: seismic forces, reinforcement percents, periods of vibration,
displacements and vertical forces of r/s isolators.